We get lots of calls asking for solutions - not products. As engineers we love challenges.
Recently a customer called with a unique testing need. A materials research scientist requires testing for a small irradiated ceramic material for their tensile properties.
The challenge
The customer requires their irradiated small ceramic sample to be tested with a tensile grip capable of handling 250 pounds (1200 N). The especially small sample size is not only tiny (0.65 in long 0.026 in thick 0.048 in wide) but brittle in nature. The slightest torsional or shear force could snap the fragile ceramic material in half. A pure tensile force is needed to achieve the desired results. The sample itself has two holes that make it possible to grip with pins.
The researcher’s request is further complicated with testing conditions. The tensile grip must withstand temperatures up to 500 degrees Celsius. The grip will be installed in an existing test machine located in a radioactive hot cell.
Solution
This complicated challenge is resolved with a simple solution. We provided a pair of clevis pin tensile grips matching the sample geometry and fabricated from nickel coated tool steel.
Our conceptualized design is delicate enough to handle the fragile sample yet tough enough to withstand raging heat within a radioactive hot cell.
This customized solution intended to break samples and not the bank was delivered at a price of $1 500.
- Details
The biggest difference between a flexure test and a bend test is in the type of material used and the test information produced. Generally a flexure test is designed to measure the bend strength of a brittle material, whereas, a bend test is designed to measure the crack resistance of a ductile material. A bend test is designed to apply forces to the sample in a way that causes it to deform in a way that will highlight any imperfections or cracks in the material for the purpose of determining the materials ductility. Performing a flexure test on a sample requires it to be loaded until the sample is pushed beyond just deforming and completely ruptures allowing for the determination of the samples maximum bend strength.
- Details
The typical flexure test sample geometry is chosen to prevent shear failure which is an important consideration in the measurement of flexural bending properties. Industry standard test requirements vary depending on the material being tested, from a span length to specimen thickness ratio ranging from a minimum of 16:1 to a maximum of 64:1 with the majority of industry standards at 32:1.